SAFETY DATA SHEETS
According to the UN GHS revision 9
SECTION 1: Identification
1.1 GHS Product identifier
Product name | Chlorotrimethylsilane |
---|
1.2 Other means of identification
Product number | - |
---|---|
Other names | Silane, chlorotrimethyl-; Chlorotrimethylsilane; chloro(trimethyl)silane |
1.3 Recommended use of the chemical and restrictions on use
Identified uses | Industrial and scientific research use. |
---|---|
Uses advised against | no data available |
1.4 Supplier's details
Company | Zhongshan Greenrock Technology Co., Ltd. |
---|---|
Address | No. 138, Jinsan Avenue, Sanjiao Town, Zhongshan City, Guangdong Province, China |
Telephone | +86-2087066781 |
export@greenrockchem.com |
1.5 Emergency phone number
Emergency phone number | +86-2087066781 |
---|---|
Service hours | Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
SECTION 2: Hazard identification
2.1 Classification of the substance or mixture
Flammable liquids, Category 2
Acute toxicity - Category 3, Oral
Acute toxicity - Category 4, Dermal
Skin corrosion, Sub-category 1A
Acute toxicity - Category 3, Inhalation
2.2 GHS label elements, including precautionary statements
Pictogram(s) | ![]() ![]() ![]() |
---|---|
Signal word | Danger |
Hazard statement(s) | H225 Highly flammable liquid and vapour H301 Toxic if swallowed H312 Harmful in contact with skin H314 Causes severe skin burns and eye damage H331 Toxic if inhaled |
Precautionary statement(s) | |
Prevention | P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges. P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/... P264 Wash ... thoroughly after handling. P270 Do not eat, drink or smoke when using this product. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. |
Response | P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower]. P370+P378 In case of fire: Use ... to extinguish. P301+P316 IF SWALLOWED: Get emergency medical help immediately. P321 Specific treatment (see ... on this label). P330 Rinse mouth. P302+P352 IF ON SKIN: Wash with plenty of water/... P317 Get medical help. P362+P364 Take off contaminated clothing and wash it before reuse. P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P363 Wash contaminated clothing before reuse. P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P316 Get emergency medical help immediately. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. |
Storage | P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. P403+P233 Store in a well-ventilated place. Keep container tightly closed. |
Disposal | P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal. |
2.3 Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
3.1 Substances
Chemical name | Common names and synonyms | CAS number | EC number | Concentration |
---|---|---|---|---|
Chlorotrimethylsilane | Chlorotrimethylsilane | 75-77-4 | 200-900-5 | 100% |
SECTION 4: First-aid measures
4.1 Description of necessary first-aid measures
If inhaled
Fresh air, rest. Half-upright position. Artificial respiration may be needed. Refer for medical attention. See Notes.
Following skin contact
Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer for medical attention .
Following eye contact
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Following ingestion
Rinse mouth. Do NOT induce vomiting. Give nothing to drink. Refer for medical attention .
4.2 Most important symptoms/effects, acute and delayed
Similar to other silanes. Toxicity is rated high for inhalation, ingestion and local irritation. May cause death or permanent injury after a very short exposure to small quantities. (EPA, 1998)
4.3 Indication of immediate medical attention and special treatment needed, if necessary
No specific antidote is available /for chlorosilanes/, but first aid treatment consists of copious irrigation with water, & subsequent treatment is as for chemical burns in general. Chlorosilanes
SECTION 5: Fire-fighting measures
5.1 Suitable extinguishing media
Aqueous film forming foam (AFFF), carbon dioxide, dry sand, special powder. NO hydrous agents. NO water.
5.2 Specific hazards arising from the chemical
Violent reaction with water. Toxic and irritating hydrogen chloride and phosgene may be formed in fires. Difficult to extinguish, re-ignition may occur. Flashback along vapor trail may occur. Containers may explode in fire. Vapor may explode if ignited in enclosed area. When heated to decomposition or on contact with acids or acid fumes, chloride fumes are emitted. Reacts with surface moisture, releasing hydrogen chloride, which will corrode common metals and form flammable hydrogen gas. Avoid contact with water; it readily hydrolyzes, liberating hydrochloric acid. Hazardous polymerization may not occur. (EPA, 1998)
5.3 Special protective actions for fire-fighters
Use AFFF, carbon dioxide, dry sand, special powder. NO hydrous agents. NO water. In case of fire: keep drums, etc., cool by spraying with water. NO direct contact with water.
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Evacuate danger area! Consult an expert! Collect leaking and spilled liquid in sealable dry non-plastic containers as far as possible. Absorb remaining liquid in dry sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer. Personal protection: complete protective clothing including self-contained breathing apparatus.
6.2 Environmental precautions
Evacuate danger area! Consult an expert! Collect leaking and spilled liquid in sealable dry non-plastic containers as far as possible. Absorb remaining liquid in dry sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer. Personal protection: complete protective clothing including self-contained breathing apparatus.
6.3 Methods and materials for containment and cleaning up
Shut off ignition sources. Call fire department. Avoid contact with liquid. Keep people away. Stop discharge if possible. Isolate and remove discharged material. Notify local health and pollution control agencies.
SECTION 7: Handling and storage
7.1 Precautions for safe handling
NO open flames, NO sparks and NO smoking. NO contact with hot surfaces. Closed system, ventilation, explosion-proof electrical equipment and lighting. Do NOT use compressed air for filling, discharging, or handling. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
7.2 Conditions for safe storage, including any incompatibilities
Fireproof. Separated from food and feedstuffs and other compounds. Cool. Dry. Well closed.Storage temperature; ambient.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Occupational Exposure limit values
no data available
Biological limit values
no data available
8.2 Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
8.3 Individual protection measures, such as personal protective equipment (PPE)
Eye/face protection
Wear face shield or eye protection in combination with breathing protection.
Skin protection
Protective gloves. Protective clothing.
Respiratory protection
Use ventilation, local exhaust or breathing protection.
Thermal hazards
no data available
SECTION 9: Physical and chemical properties and safety characteristics
Physical state | Trimethylchlorosilane is a colorless fuming liquid with a pungent odor. Boiling point 135° F, Flash point -18°F. Density 0.854 g / cm3. The vapor and liquid may cause burns. Vapors are heavier than air. |
---|---|
Colour | Colorless liquid |
Odour | SHARP, HYDROCHLORIC ACID-LIKE ODOR; ACRID. |
Melting point/freezing point | -58°C(lit.) |
Boiling point or initial boiling point and boiling range | 57°C(lit.) |
Flammability | Highly flammable. Gives off irritating or toxic fumes (or gases) in a fire. |
Lower and upper explosion limit/flammability limit | Lower flammable limit: 1.8% by volume; Upper flammable limit: 6.0% by volume |
Flash point | -28°C |
Auto-ignition temperature | 752°F |
Decomposition temperature | no data available |
pH | no data available |
Kinematic viscosity | no data available |
Solubility | Decomposes (NTP, 1992) |
Partition coefficient n-octanol/water | no data available |
Vapour pressure | 100 mm Hg ( 25 °C) |
Density and/or relative density | 0.856g/mLat 25°C(lit.) |
Relative vapour density | 3.7 (vs air) |
Particle characteristics | no data available |
SECTION 10: Stability and reactivity
10.1 Reactivity
Decomposes on heating. This produces toxic and corrosive fumes including hydrogen chloride and phosgene. Reacts violently with water. This produces hydrogen chloride (see ICSC 0163). Reacts violently with alcohols and amines. This generates fire and explosion hazard. Attacks many metals in the presence of water.
10.2 Chemical stability
no data available
10.3 Possibility of hazardous reactions
A flammable liquid and very dangerous fire haszard when exposed to heat or flame.The vapour is heavier than air and may travel along the ground; distant ignition possible.TRIMETHYLCHLOROSILANE reacts vigorously and exothermically with water to produce hydrogen chloride.
10.4 Conditions to avoid
no data available
10.5 Incompatible materials
Reacts with surface moisture to evolve hydrogen chloride, which will corrode common metals & form flammable hydrogen gas.
10.6 Hazardous decomposition products
Trimethylchlorosilane/ decomposes on heating producing toxic and corrosive fumes including hydrogen chloride, phosgene.
SECTION 11: Toxicological information
Acute toxicity
- Oral: LD50 Rat oral 5660 uL/kg
- Inhalation: LC50 Rat inhalation 12.9 mg/L/1 hr
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
The substance and the vapour are corrosive to the eyes, skin and respiratory tract. Corrosive on ingestion. Inhalation of the vapour may cause lung oedema. Exposure could cause death. Medical observation is indicated. See Notes.
STOT-repeated exposure
no data available
Aspiration hazard
No indication can be given about the rate at which a harmful concentration of this substance in the air is reached on evaporation at 20°C.
SECTION 12: Ecological information
12.1 Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
12.2 Persistence and degradability
no data available
12.3 Bioaccumulative potential
Trimethylchlorosilane has been reported to hydrolyze immediately upon contact with water(1) and therefore bioconcentration of trimethylchlorosilane is not expected(SRC).
12.4 Mobility in soil
All silicon chlorides are immediately and completely hydrolyzed by water(1) and trimethylchlorosilane has been reported to hydrolyze in water releasing hydrochloric acid(2). Decomposition of trimethylcholorsilane is expected to occur more rapidly than adsorption(SRC).
12.5 Other adverse effects
no data available
SECTION 13: Disposal considerations
13.1 Disposal methods
Product
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Contaminated packaging
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
14.1 UN Number
ADR/RID: UN1298 (For reference only, please check.) | IMDG: UN1298 (For reference only, please check.) | IATA: UN1298 (For reference only, please check.) |
14.2 UN Proper Shipping Name
ADR/RID: TRIMETHYLCHLOROSILANE (For reference only, please check.) | IMDG: TRIMETHYLCHLOROSILANE (For reference only, please check.) | IATA: TRIMETHYLCHLOROSILANE (For reference only, please check.) |
14.3 Transport hazard class(es)
ADR/RID: 3 (For reference only, please check.) | IMDG: 3 (For reference only, please check.) | IATA: 3 (For reference only, please check.) |
14.4 Packing group, if applicable
ADR/RID: II (For reference only, please check.) | IMDG: II (For reference only, please check.) | IATA: II (For reference only, please check.) |
14.5 Environmental hazards
ADR/RID: No | IMDG: No | IATA: No |
14.6 Special precautions for user
no data available
14.7 Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
15.1 Safety, health and environmental regulations specific for the product in question
Chemical name | Common names and synonyms | CAS number | EC number |
---|---|---|---|
Chlorotrimethylsilane | Chlorotrimethylsilane | 75-77-4 | 200-900-5 |
European Inventory of Existing Commercial Chemical Substances (EINECS) | Listed. | ||
EC Inventory | Listed. | ||
United States Toxic Substances Control Act (TSCA) Inventory | Listed. | ||
China Catalog of Hazardous chemicals 2015 | Listed. | ||
New Zealand Inventory of Chemicals (NZIoC) | Listed. | ||
Philippines Inventory of Chemicals and Chemical Substances (PICCS) | Listed. | ||
Vietnam National Chemical Inventory | Listed. | ||
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) | Listed. | ||
Korea Existing Chemicals List (KECL) | Listed. |
SECTION 16: Other information
Information on revision
Creation Date | July 15, 2019 |
---|---|
Revision Date | July 15, 2019 |
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Other Information
Reacts violently with fire extinguishing agents such as water.The symptoms of lung oedema often do not become manifest until a few hours have passed and they are aggravated by physical effort. Rest and medical observation are therefore essential.Immediate administration of an appropriate inhalation therapy by a doctor, or by an authorized person, should be considered.Toxicological properties are inferred from those of Methyldichlorosilane (ICSC 0297).
Any questions regarding this SDS, Please send your inquiry to export@greenrockchem.com
Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.